USE:for soldering, brazing and point heating. Art. Nr. Type(∅) Consum.PB (g/h) Output(kW/h) Length(mm) 17160 11 mm 511 6,58 190 17129 3 mm 41 0,53 180 17137 5 mm 120 1,55 180 17145 7 mm 222 2,86 185 17152 9 mm 380 4,89 185 TECHNICAL DATA Working pressure: 1,5 - 2,0 bar Gas: P, PB
The CELTIC range can be used with all common non-corrosive industrial gas. As for regulation, these products are very accurate. APPLICATION First stage regulation for propane at the outlet of a cistern (RGCL-N) Pressure limiting device (AML1 with RD05) PRODUCT ADVANTAGES Watertightness in case of bad weather All components comfortably accessible Easy and fast dismantling Simple and heavy-duty Low pressure closing Stainless steel a
Whole medical range is available on gcehealthcare.com The manifold MM90 STANDBY is designed to be used as a third source of supply in medical central gas systems. The manifold will deliver gas when the nominal supply system pressure falls below a set level (7 bar). This is a back up source.Together with MM90 STANDBY, always use the MM90 HP unit and alarm providing all alarms according to standard (like Gas alarm). As 2nd stage is recommended to
Whole medical range is available on gcehealthcare.com Manifold MM40 HP unit is an automatic manifold. It is working on the principal of different pressures between the operation and reserve regulator. By the manual lever, the operator can decide which side will be the operational side and which will be the reserve side. When the operating side is empty, the manifold will without any action start to supply gas from the reserve side with the lower
Whole medical range is available on gcehealthcare.com The Simplex MMR gas manifold is suitable for such health care where the capacity requirement is limited, such as laboratories and small health care clinics, veterinary etc. This gas manifold consists of only one group of cylinders. The regulator is mounted in the collection unit. Each inlet connection has a filter, a non-return valve and a shut-off valve. This arrangement makes it possilble
The MC80 gas manifold is suitable for medium to large sized hospital. It has a flow capacity up to 200 m3/h and is conveniently designed in modules. The MC80 reduces the gas pressure in two steps to a constant distribution pressure. Service and tests can be carried out with no disturbance in the supply of gas to the gas distribution system. THE DUPLEX MC80 CONSIST OF THE THREE FOLLOWING UNITS: 1. MC80 - HIGH PRESSURE UNIT This module contains
Whole medical range is available on gcehealthcare.com The gas cylinder manifold MC25 has a capacity of 25 m3/h and is primarily intended for small and medium-sized hospitals. The gas cylinder pressure is regulated in two steps. The change-over between operating side and reserve side is made automatically without any differences in the operating pressure. The alarm signal comes from the pressure switches to the alarm unit. The alarm signals from
Whole medical range is available on gcehealthcare.com MC150 - STABILIZER is a second stage pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units. MC150 - STABILIZER is a second stage reduction unit where the primary gas supply is provided by high pressure gas manifolds (such as MC80, MM90 or liquid oxygen tank (LOX)). When there
These gas supply panels are mounted onto a stainless steel panel and consist of a pressure regulator, inlet and outlet pressure gauges, a relief valve and shut-off valves (type -16 at the outlet, type -24 at the inlet, type -25 at inlet and outlet) for the process gas. A choice of stainless steel coils or flexible high pressure hoses is available for the connection to the gas cylinder. The use of contact gauge (accessories) in conjunction with al
A broad application spectrum through the 4-port configuration (type -01/-04) or 6-Port-configuration (type -03/-05), which can be delivered respectivly, with (type -04/-05) or without (type -01/-03) a relief valve. With type-03 and type-05 the use of contact gauge (accessories) in conjunction with alarm box (accessories) facilitates the monitoring of gas reserves. APPLICATION The LMD 320 reduces line pressure to give a lower supply pressure. Th